Your browser doesn't support javascript.
Шоу: 20 | 50 | 100
Результаты 1 - 5 de 5
Фильтр
1.
Heart Rhythm ; 19(2): 206-216, 2022 02.
Статья в английский | MEDLINE | ID: covidwho-1482622

Реферат

BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.


Тема - темы
Atrioventricular Block , COVID-19 , Infection Control , Postoperative Complications , Prosthesis Implantation , SARS-CoV-2/isolation & purification , Sick Sinus Syndrome , Aged , Atrioventricular Block/epidemiology , Atrioventricular Block/therapy , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/therapy , Comorbidity , Defibrillators, Implantable/statistics & numerical data , Female , Global Health/statistics & numerical data , Humans , Infection Control/instrumentation , Infection Control/methods , Infection Control/organization & administration , Male , Middle Aged , Mortality , Outcome Assessment, Health Care , Pacemaker, Artificial/statistics & numerical data , Postoperative Complications/diagnosis , Postoperative Complications/mortality , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Prosthesis Implantation/mortality , Risk Factors , Sick Sinus Syndrome/epidemiology , Sick Sinus Syndrome/therapy , Surveys and Questionnaires
2.
J Cardiovasc Med (Hagerstown) ; 23(1): 22-27, 2022 01 01.
Статья в английский | MEDLINE | ID: covidwho-1430637

Реферат

AIMS: The coronavirus disease-19 (COVID-19) outbreak has been recently associated with lower hospitalization rates for acute coronary syndromes. Aim of the study was to investigate whether a similar behaviour is observed in admissions for urgent pacemaker implant. METHODS: This retrospective study included 1315 patients from 18 hospitals in Northern Italy with a high number of COVID-19 cases. Hospitalization rates for urgent pacemaker implant were compared between the following periods: 20 February to 20 April 2020 (case period); from 1 January to 19 February 2020 (intra-year control period); from 20 February to 20 April 2019 (inter-year control period). RESULTS: The incidence rate of urgent implants was 5.0/day in the case period, 6.0/day in the intra-year control period and 5.8/day in the inter-year control period. Incidence rate in the case period was significantly lower than both the intra-year [incidence rate ratio (IRR): 0.81, 95% CI 0.67-0.99, P = 0.040] and inter-year control periods (IRR: 0.79, 95% CI 0.66-0.95, P = 0.012); this reduction was highest after the national lockdown (IRR 0.68, 95% CI 0.52-0.91, P = 0.009). The prevalence of residents in rural areas undergoing urgent pacemaker implant was lower in the case period (36%) than in both the intra-year (47%, P = 0.03) and inter-year control periods (51%, P = 0.002). Elective pacemaker implants also decreased in the case period, with the incidence rate here being 3.5/day vs. 6.4/day in the intra-year (-45%) and 6.9/day in the inter-year period (-49%). CONCLUSION: Despite severe clinical patterns, the COVID-19 outbreak has negatively affected the population presentation to Emergency Departments for bradyarrhythmias requiring urgent pacemaker implant in Northern Italy. This mainly occurred after the national lockdown and concerned patients living in rural areas.


Тема - темы
Bradycardia/epidemiology , Bradycardia/therapy , COVID-19/epidemiology , Disease Outbreaks/statistics & numerical data , Elective Surgical Procedures/statistics & numerical data , Emergencies/epidemiology , Pacemaker, Artificial/statistics & numerical data , Aged , Aged, 80 and over , Female , Hospitalization/statistics & numerical data , Humans , Incidence , Italy/epidemiology , Male , Retrospective Studies
Критерии поиска